Regeneration function protection, meet island detection, discharge energy recovery technology to reduce operating costs
- Efficiency > 90%, the current THD < 5%, PF > 0.95
- A stable ac voltage during regeneration
- Meet VDE - 4105 - AE testing requirements (optional)

Safety design of risk management
- Level 1 hardware protection: over voltage protection, under-voltage protection, over current protection, temperature protection, capacity,...Etc.
- Level 2 software protection (optional) : message protection, battery management system data recorder acquisition data protection, temperature cabinet state protection
- Level 3 hardware protection (optional) : leakage protection, islanding protection
- Four levels of protection, independent overvoltage measurement, abnormal blocking output immediately
Flexible configuration high power testing equipment for energy storage systems and electric application test
- Cap of 1700 v / 4800 a / 1.2 MW
- Two kinds of voltage current operating range, application more flexible (partial model limited) : 200 kw / 850 v / 800 a and 200 kw / 1700 v / 400 a

- Third party equipment integration technology bring convenient and save time (optional) : thermostat, data recorder, BMS data recording/control, cold water machine, the vehicle ECU simulator...Etc.