Energy recovery type battery module testing system Model 17020 e

Energy recovery type battery module test system
Energy recovery type battery module test system
Energy recovery type battery module test system
Energy recovery type battery module test system
Energy recovery type battery module test system
Energy recovery type battery module test system
The product features
  • Operating modes: constant current/constant voltage/constant power discharge
    Channel power:
    • 10 kw / 20 kw (single channel)
    • 30 kw / 40 kw / 50 kw / 60 kw / 70 kw / 80 kw (parallel)
    Channel: voltage 60 v / 100 v / 200 v
    Channel current:
    • 60 v: 180 a / 360 a per channel.720 a (parallel)
    • 100 v / 200 v, 100 a per channel.
    • 100 v / 200 v, 200 a / 300 a / 400 a / 500 a / 600 a / 700 a / 800 a (parallel)
  • The battery discharge energy recovery function, the recovery efficiency of 85%
  • Have parallel function
  • The simulation of dynamic power/current charge and discharge function
  • High precision voltage measurement accuracy of current
  • Fast switching between charge and discharge current, don't interrupt
  • The charging and discharging mode switch (CC - CV - CP), no surge current is smooth
  • Report data analysis function
  • Support power data reset function
  • Independent channel protection function

Safety - to strengthen risk control

  • Can send the test conditions and cut-off/protection conditions, load directly to the charge and discharge machine, through the internal software/hardware to multilayer protection function
  • Can integrate the external hardware to achieve the real-time monitoring parameters, such as BMS, Data Logger, Chamber, the I/O signal, to achieve the alarm/as/power-off protection function
  • Read values and communicating with the BMS Data Logger measurement, can monitor the voltage of battery pack/temperature value, and can be real-time judgment and protection action in accordance with the set value
  • Built-in multiple alarm/protected mode: OVP, UVP, OTP, WIR_LOSS, CAL_ERR, POW_ERR, RM

Accurate - improve product quality

  • High frequency sampling measurement technology: the fastest 50 KHZ sampling rate, to ensure that the dynamic measurement accuracy
  • Voltage accuracy: plus or minus (0.02% of RDG. + / - 0.02% of f.s.)
  • Current precision: plus or minus (0.05% RDG. Plus or minus 0.05% mg.)
  • Quick response testing technology: the current rate of climb 50 ms (90% to 90%), applicable to a variety of test application requirements
  • Support dynamic condition simulation (Waveform) test function, the simulation of the actual driving conditions current or power status, support NEDC test standard, FUDS, HPPC regulations

High frequency sampling measurement technology

General battery charging and discharging machine, direct use of power calculation software reads the current value, software of data read speed limited, however, will have the affect of dynamic current capacity calculation error is too large.Chroma increased by V/I sampling rate, and through the two integral method, provide better capacity calculation, accurate current change when the data is not missing, not affected by the data transfer rate.

  • V/I 50 KHZ sampling rate (every 20 mu s sampling point)
  • Piecewise integral mode operation: for I integral - electric capacity;The V x I integral - energy

Quick response testing technology

In the current rapid response at the same time, can achieve the optimized charging and discharging mode conversion control, avoid damage to the object under test test process.

  • The Current Ripple, whose < 1% FS, Overshoot < 1%

Working condition of dynamic simulation function

The use of the battery pack is fast and irregular current charge and discharge change state, through the results, the use of the battery status can be real reaction in the battery.

  • Dynamic charge and discharge Waveform of simulation battery actual use, in the dynamic current mode (Waveform), maximum discharge and the maximum charging current commutation time only need 10 ms
  • Work within the computer specified step can be set to read current/power waveform Excel file
  • Each channel can store 720000 points, for long time dynamic testing
  • Working condition of waveform changes the time interval of 10 ms ~ 10 SEC.

The graphical user interface - 'Pro

Chroma 17020 e test system software platform 'Pro, conforms to the requirement of each test the secondary Battery, with a high degree of stability and security, and have power data save reply function, to prevent any possibility of data missing.

  • Real-time monitoring: real-time browsing system test status, do not need to wait for, channel data and system integration can browse at the same time
  • Graphic management: channel test status through different graphic management, be clear at a glance, easy to see to understand easy to understand, control state immediately, understand the test state
  • Data analysis functions: customized charts function, rapid test curve drawing (Life cycle, Capacity report...Etc.)
  • Fault record tracking & permissions Settings: independent record abnormal state channel;To set the user authority to operate

System integration

  • Through software can integrate constant temperature and humidity box, charging and discharging test do synchronization setting conditions
  • Through software can integrate data record, in the process of charging and discharging, read more groups of voltage and temperature record, the condition can be converted to protect start-up condition or cut-off condition

  • Through the communication interface software can be integrated device, the choose and buy A692000 / A692001 each of the 4 channel / 8 channels of communication unit, can do the CANbus, RS485 communication, in the process of charging and discharging, read more groups of battery management system (BMS) data, its condition convertible protection start or cut-off condition

Product inquiry

Please check the product you would like to ask, and click "add to inquiry" button below.
You can join several products at a time, and right click on the web inquiry car here is a complete inquiry.

All specifications are subject to change without prior notice.
choose
model
The narrative

Energy recovery type battery module test system

Energy recovery type battery module testing system 200 v / 100 a / 10 kw / 2 ch / 20 kw

Energy recovery type battery module test system of 200 v / 100 a / 10 kw / 4 ch / 40 kw

Energy recovery type battery module test system of 200 v / 100 a / 10 kw / 6 ch / 60 kw

Energy recovery type battery module test system of 200 v / 100 a / 10 kw / 8 ch / 80 kw

Energy recovery type battery module testing system 100 v / 100 a / 10 kw / 2 ch / 20 kw

Energy recovery type battery module test system of 100 v / 100 a / 10 kw / 4 ch / 40 kw

Energy recovery type battery module test system of 100 v / 100 a / 10 kw / 6 ch / 60 kw

Energy recovery type battery module test system of 100 v / 100 a / 10 kw / 8 ch / 80 kw

Energy recovery type battery module testing system 60 v / 180 a / 10 kw / 2 ch / 20 kw

Energy recovery type battery module testing system 60 v / 180 a / 10 kw / 4 ch / 40 kw

Energy recovery type battery module testing system 60 v / 180 a / 10 kw / 6 ch / 60 kw

Energy recovery type battery module testing system 60 v / 180 a / 10 kw / 8 ch / 80 kw

Energy recovery type battery module testing system 60 v / 360 a / 20 kw / 2 ch / 40 kw

Energy recovery type battery module testing system 60 v / 360 a / 20 kw / 4 ch / 80 kw

Energy recovery type battery module testing system 60 v / 100 v / 200 v power and other multi-channel combination